EasyManuals Logo

Casio QT-6600 Service Manual

Casio QT-6600
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
— 75
[ 30 ] Drawer Test
[Function]
Tests whether drawers operate properly.
In order to complete the test, the operator must determine pass(OK)/fail(NG) of the result.
[Operation]
Operation : x n 0 9 1 ST
x: Drawer No.
0 Opens all drawers.
1 Opens Drawer 1
2 Opens Drawer 2
n: Number of times
0 or no value To perform a single test
A value other than 0 (1 ~ 9) Tests repeat infinitely (press ESC to terminate)
[LCD]
When all drawers are open When Drawer No. is specified
DRW 0n091
DRW ALL OK
END 0n091
DRW xn091
DRW n OK
END xn091
n: Drawer number
[PRINT]
When all drawers are open When Drawer No. is specified
DRW 0n091
DRW ALL OK
END 0n091
DRW xn091
DRW n OK
END xn091