Loading...
— 18 —
RACCLEAR&WRITE/READTEST[ 12 ]
[Notes]
Proper operation is not guaranteed for the internal data and main device of RAC used in this test.
[Function]
Clears RAC, writes data, and reads the data.
This test also checks if the device wrote and read the data correctly.
[Operation]
Command:
n
3
1
4
SUBTOTAL
n: Number of times to run
0 Once
1 ~ 9 Inniteloop
●
If a command to specify the number of times to run the test is omitted, the test is performed only once.
● Toforciblyterminatetheinniteloop,press[C(Clear)]orturntheModeSwitchto[OFF].
[PRINT]
RAM 314
RAM WR OK
END 314