i06545387
Maintenance Interval Schedule
SMCS Code: 1000; 7500
Ensure that all safety information, warnings, and
instructions are read and understood before any
operation or any maintenance procedures are
performed.
The user is responsible for the performance of
maintenance, including all adjustments, the use of
proper lubricants, fluids, filters, and the replacement
of components due to normal wear and aging. Failure
to adhere to proper maintenance intervals and
procedures may result in diminished performance of
the product and/or accelerated wear of components.
Use mileage, fuel consumption, service hours, or
calendar time, WHICH EVER OCCURS FIRST, in
order to determine the maintenance intervals.
Products that operate in severe operating conditions
may require more frequent maintenance.
Note: Before each consecutive interval is performed,
all maintenance from the previous interval must be
performed.
When Required
“ Battery - Replace” . . . . . . . . . . . . . . . . . . . . . . . . 107
“ Battery or Battery Cable - Disconnect” . . . . . . . . 108
“Cooling System Coolant Sample (Level 2) -
Obtain” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
“ Engine - Clean” . . . . . . . . . . . . . . . . . . . . . . . . . . 117
“ Fuel System - Prime” . . . . . . . . . . . . . . . . . . . . . . 127
“ Generator Set - Test” . . . . . . . . . . . . . . . . . . . . . . 137
“ Rotating Rectifier - Test” . . . . . . . . . . . . . . . . . . . 148
“ Severe Service Application - Check” . . . . . . . . . 149
Daily
“ Cooling System Coolant Level - Check”. . . . . . . 112
“ Engine Air Cleaner Element (Dual Element) - Clean/
Replace” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
“ Engine Air Cleaner Service Indicator -
Inspect” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
“ Engine Oil Level - Check” . . . . . . . . . . . . . . . . . . 122
“ Fuel System Primary Filter/Water Separator -
Drain” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
“ Generator Load - Check”. . . . . . . . . . . . . . . . . . . 136
“ Jacket Water Heater - Check” . . . . . . . . . . . . . . . 144
“ Power Factor - Check”. . . . . . . . . . . . . . . . . . . . . 147
“Walk-Around Inspection” . . . . . . . . . . . . . . . . . . . 151
Every Week
“ Electrical Connections - Check” . . . . . . . . . . . . . 116
“ Generator - Inspect”. . . . . . . . . . . . . . . . . . . . . . . 134
“ Generator Bearing Temperature - Measure/
Record” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
“ Generator Lead (Flat Braided Cable) -
Check” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
“ Instrument Panel - Inspect” . . . . . . . . . . . . . . . . . 141
Every 100 Service Hours or 3
Months
“ Insulation - Test”. . . . . . . . . . . . . . . . . . . . . . . . . . 141
Every 250 Service Hours
“Cooling System Coolant Sample (Level 1) -
Obtain” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Every 2000 Service Hours
“ Generator Lead (Round Cable) - Check” . . . . . . 136
Every 2000 Service Hours or 6
Months
“ Generator Set Vibration - Inspect” . . . . . . . . . . . 138
“ Generator - Dry” . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Every 2000 Service Hours or 1 Year
“Cooling System Coolant Sample (Level 2) -
Obtain” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Every Year
“ Fuel System Primary Filter (Water Separator)
Element - Replace” . . . . . . . . . . . . . . . . . . . . . . . . 128
104
SEBU7125-13
Maintenance Section
Maintenance Interval Schedule