9
Inside the CEL-200:
Fuses: An essential component for the safety of the system. Fuses protect other
electronics components in the event of a short circuit. Never use a fuse with a higher
rating than what’s recommended or damage can occur to the system and to other
connected equipment. If a fuse blows, check for a short circuit somewhere in the
connections to the external devices or the wiring itself. A device connected to the
system could be faulty.
Fuse F1: type 5x20mm, 250VAC, 500mA ( Bel Fuse #5ST 500-R )
Fuses F2, F3: type 3AB, Fast Acting, 250VAC, 12A ( Littelfuse #0314012 )
Battery: The system is equipped with a CR2032 type 3V lithium battery. The battery is
used to keep the clock running during power failures. It also powers the settings
memory of the system. Removing the battery will reset all the settings.
Terminals:
: Variable Lighting Power Output Load
: Ground
L1 : Main Power, 120V / 240VAC, 50/60Hz, 1Ø
L2/N : Main Neutral & Variable Lighting Power Output Neutral
0-10V Input +/- : 0-10V Input used for Slave Mode
0-10V Output +/- : 0-10V Output, in Master Mode to control a slave unit.
Minimum Adjust: This little potentiometer lets you adjust the output power at
minimum intensity. Since all lights don't turn on at the same level, this adjustment
allows you to get the perfect flicker free low level lighting. Switch the system to manual
mode and set the intensity to 1%. Using a small screwdriver, turn the potentiometer to
obtain the perfect low level lighting.