OPERATING INSTRUCTIONS
tild VP v2.0EN
1. Technical specifications
Dimensions 410 x 310 x 150mm
Electricity supply
230V AC.
PF10Y700: 30mA ground fault circuit breaker to be provided upstream.
PF10Y701 and PF10Y702: ground fault circuit breaker built into the control
box.
Weight 6.5 kg
Protection rating IP-55
Compatible filtering pumps 1.5 HP - Single phase. C16 protection.
Auxiliary output 1.5HP max if booster pump - Single phased. Max 230V. C16 protection
Light output 12V / 100VA. C10 protection
Heat pump output (PF10Y700 / 702 only) 230V. D16 protection for heat pump
Bluetooth®
Low Energy (v4.x)
Conforms to the R&TTE Directive 1999/5/EC
Wifi 802.11 b/g/n and "dual band" (2.4 Ghz only)
2. Pack contents
1 control box with tild VP module shipped with cable glands
and grommet.
1 temperature sensor with Ø50mm 1/2" fixing collar
4 fixing screws and anchors (bag)
1 Technical manual (this document) and 1 wiring diagram
2