Installation
Important
If the oven is being installed into a built under oven housing unit
ensure that the front rail at the top of the unit is not installed as it could
restrict ventilation.
Ensure that air can flow freely around the housing area. If the oven
is being installed into a fully enclosed built-under oven housing unit
it may be necessary to cut a small slot in the top of the plinth fitted
under the unit. Cut a section 400mm wide and a minimum of 15mm
high to allow air to pass under the unit. Alternatively cut a section 400
x 450mm in the base of the carcass as indicated.
Failure to allow adequate ventilation to the appliance may result in
overheating or damage to adjacent units and could invalidate the
warranty.
This appliance is type X installation.
The walls of the kitchen units must be able to withstand temperatures
of 75C above ambient (typically this is between 90C and 100C).
When correctly installed ensure that there is a gap of 4mm minimum
between the sides of the oven and adjacent furniture doors.
Lift the oven carefully into position on the shelf, taking care NOT to lift
it by the door handle. If you lower the oven door, you will see 4 screw
holes, 2 on each side of the oven. The oven should then be secured