TheSubMastercodeallowstheuser
tochangeitsowncodewithoutentering
inprogrammingmode.Forsecurity
reasonsthecodeneedtobechanged
periodically.Thisfeaturemakesiteasier
andfastertochangeitscode.
 

2beepsareemittedtoconrmentry
inprogrammingmode.





Onebeepisemitted.Enterthenew
2-digitsubmastercode.Onebeep
isemittedtoconrmprogramming
ofthesubmastercode.




2beepsareemittedtoconrm
thatthekeypadisinstand-by
operatingmode.

Theaudiblesignalisenabled
inprogrammingmode
andwhentherelayisenergised
afteravalidcode.
Toenabletheaudiblefeedback
onakeypress:
 

2beepsareemittedtoconrmentry
inprogrammingmode.
 
Onebeepisemitted.Presstodisable
theaudiblesignalduringakeypress.
Presstoenabletheaudiblesignal
duringakeypress.Onebeepconrms
thenewsetting.
 
2beepsareemittedtoconrmexit
fromprogrammingmode.



Programminginstructionsarethesame
asfortheGALEOkeypadwith1
relayoutput.
:2relayoutputsN/O
andN/Ccontacts8A@250V~.
Fromuserlocation00
touserlocation59toactivaterelay1.
fromuserlocation60
touserlocation99toactivaterelay2
 ReleaseTimeofrelay2enter
submastercodeenter
(defaultvalues1and3).
3relayoutputsN/O
andN/Ccontacts8A@250V~.
fromuserlocation00
touserlocation59toactivaterelay1.
fromuserlocation60
touserlocation79toactivaterelay2.
fromuserlocation80
touserlocation99toactivaterelay3.
Releasetimeforrelay3enter
submastercodeenter
(defaultvalues4and6).
12
cdvi.se
cdvigroup.com

IlluminatedWeatherproofKeypadwithremoteelectronics
