8.
No
sound
from
the
speaker.
Check
to
see
that
the
output
cords
are
securely
connected
to
the
amplifier
(receiver).
No:
Connect
the
cord.
Yes:
Check
to
see
that
connections
are
made
to
the
PHONO
input
terminals
of
the
amplifier.
No:
Connect
to
PHONO.
Yes:
Check
to
see
that
the
select
switch
of
the
amplifier
is
placed
to
PHONO.
No:
Place
select
switch
to
PHONO.
Yes:
Remove
the
headshell,
touch
the
upper
two
pins
at
the
end
of
the
arm
with
a
metal
screwdriver
and
listen
for
the
speaker
to
produce
a
humming
noise.
(Fig.
20)
|
ne
Perform
continuity
test
between
the
arm
and
output
cords.
No:
:
:
Make
correct
connections.
Yes:
Check
the
connections
between
the
cartridge
and
headshell.
—(
Ves:
Cartridge
defective.
9.
The
tone
arm
will
not
go
down
even
with
the
lifter
lever
in
¥
position.
Check
to
see
that
release
assy
(No.
22)
moves
to
cooperate
with
operating
plate
assy
(No.
20)
when
the
lifter
lever
A
is
pushed
down.
No:
Check
to
see
that
the
screw
(No.
211)
is
correctly
fastened
to
lifter
lever
B.
:
No:
Fasten
the
screw.
i
No:
Mount
the
release.
Yes:
Check
to
see
that
the
release
is
correctly
mounted.
—{_
Yes:
The
release
is
defective.
Yes:
Check
to
see
that
the
lifter
shaft
assy
(No.
22)
moves
down
when
the
lifter
lever
A
is
pushed
down.
pe:
Replace
lifter
shaft
assy
or
lifer
boss
(No.
23).
Yes:
Loosen
the
screw
which
fastens
tone
arm
support
and
adjust
the
clearance
between
stylus
point
and
record
surface
to
5—10mm
when
lifter
lever
is
in
position,
referring
to
STYLUS
POINT
HEIGHT
of
ADJUSTMENTS,
10.
The
turntable
is
rotating
but
the
strobo
light
will
not
light.
Check
the
12
k&
resistor
which
is
connected
with
neon
lamp
in
series.
Yes:
Neon
lamp
is
defective.
No:
Replace
12
kQ
resistor.
PARTS
REPLACEMENT
1.
TONE
ARM
Remove
tone
arm
referring
to
DISASSEMBLY
INSTRUC-
TIONS,
5
step
(1)
to
(7)
and
replace.
To
reassemble,
use
é
;
DIASSEMBLY
INSTRUCTIONS
in
reverse.
Adjust
the
Connection
pin
tone
arm
referring
to
ADJUSTMENTS,
3,
5
and
6.
2.
TURNTABLE
SHAFT
Remove
the
three
screws
which
hold
the
turntable
shaft,
and
adjust
the
gap
between
the
turntable
gear
and
ratchet
A
referring
to
the
ADJUSTMENTS,
4.
Be
sure
to
check
auto
return
operation.
3.
MOTOR
Remove
bottom
base
in
accordance
with
DISASSEMBLY
INSTRUCTIONS,
3.
Remove
the
motor
as
shown
in
DiS-
ASSEMBLY
INSTRUCTIONS,
4.
Replace
the
new
motor
and
fasten
it
by
screws.
After
binding
the
wires
to
lug
ter-
minal
tightly
and
solder
them.
4.
LIFTER
LEVER
A
(CUEING
LEVER)
With
DISASSEMBLY
INSTRUCTIONS,
6
as
a
guide,
re-
move
lifter
leverA.Replace
the
lifter
lever
A
so
that
it
becomes
parallel
with
the
edge
of
panel
board
when
cueing
lever
lines
up
to
Y
position
(Fig.
21).
5.
CUEING
(LIFTER
SHAFT)
Remove
return
plate
(No.
36
in
EXPLODED
VIEW)
from
sub-chassis.
Remove
lifter
base
(No.
17),
and
remove
tone
arm
support
(No.
27)
from
lifter
shaft.
Pull
out
the
lifter
shaft
in
the
direction
of
downward.
Replace
new
lifter
shaft
after
adhering
10°
CS
silicon
oi!.
After
finishing
reassembl-
ing,
be
sure
to
check
the
gap
between
stylus
point
and
re-
cord
surface
referring
to
ADJUSTMENTS,
3.
(Fig.
22)
e7