PREPARING THE UNIT FOR INSTALLATION
The CellarCool Unit requires a dedicated 115V, 20-amp circuit. The unit draws a large amount of amps during its initial
startup. By designating a dedicated circuit breaker, you will guarantee the unit has enough power to run eectively. Contact an
electrician for assistance with the installation of this dedicated electrical circuit.
The unit must sit upright for 24 hours prior to installation. To prepare the unit for installation:
• Remove unit from box.
• Match the electrical outlet to the plug provided on the CellarCool unit.
• Provide a dedicated circuit and wiring for the unit (see above).
• Provide a weatherproof plug for units connected outside.
Power surges and spikes can damage sensitive electrical equipment. CellarCool recommends plugging the unit into a surge
protector or power conditioner in order to protect your system. As outlined in our terms and conditions, power surges and spikes
are not covered under warranty.
We recommend that you do not use a GFI (ground fault interrupter) with this product.
The unit is equipped with two power inlets. One is located on the right side of the unit (inside of the cellar), and the other is
located on the rear of the unit (outside of the cellar). Use the selector switch located on the right side of the unit to select which
power inlet you would like to use. If you would like to plug the unit into a socket outside of the cellar, set the selector switch to
rear. If you would like to plug the unit into a socket inside of the cellar, set the selector switch to the front position. When placed
in either position, power can only enter the unit utilizing the power inlet you’ve selected.
In case the unit should lose power, check the home/main circuit breaker. If the unit does not respond properly, refer to the
Troubleshooting Guide.