Page 17For technical questions, please call 1-800-444-3353.Item 60328
NOTICE
Clean the Airbrush IMMEDIATELY after use.
Delayed or inadequate cleaning will permanently clog the Airbrush.
SAFETYOPERATIONMAINTENANCE SETUP
Compressor Troubleshooting
Problem Possible Causes Likely Solutions
The motor does
not work.
1. No electrical power.
2. Damaged power cord.
3. Electrical wiring within
the unit is defective.
4. Power switch is defective.
1. Plug power cord into a working,
120V~, grounded, electrical outlet.
2. Have a qualified service
technician replace power cord.
3. Have a qualified service technician
replace electrical wiring.
4. Have a qualified service technician
replace power switch.
The motor runs,
but it makes
irregular noises or
a knocking noise.
1. Bearing is loose or damaged.
2. Screws in the connection
rod are loose.
1. Have a qualified service
technician replace bearing.
2. Tighten screws, or replace
them if necessary.
Not enough pressure
when painting
or spraying.
1. Loose air connection(s).
2. Air hose is damaged.
3. Screws on cylinder
cover are loose.
1. Check all air connections, and
tighten them if necessary.
2. Replace air hose.
3. Tighten screws.
Poor spray pattern. 1. Loose air connections(s).
2. The paint is too thick.
3. The Airbrush nozzle
is plugged or dirty.
1. Check all air connections, and
tighten them if necessary.
2. Add paint thinner and mix thoroughly.
3. Clean or change the nozzle.
Motor runs properly,
but no air pressure or
lack of air delivery.
1. Valve plate is loose or out of
place.
2. Retainer ring is damaged
after excessive use
at high pressure.
1. Open the front cover and make
sure the valve plate is in the proper
position. Tighten screws if necessary.
2. Have a qualified service technician
replace the retainer ring.
Follow all safety precautions whenever diagnosing or servicing
the Compressor.
Disconnect power supply before service.