Page 12 For technical questions, please call 1-800-444-3353. Item 60328
NOTICE
Clean the Airbrush IMMEDIATELY after use.
Delayed or inadequate cleaning will permanently clog the Airbrush.
SAFETY OPERATION MAINTENANCESETUP
General Operation
Note: This Compressor will automatically
shut off on overload or under excessive heat.
Should this occur, turn Power Switch off. Wait
until the Compressor cools. Then, turn Power
Switch on to resume work.
Note: Drain Water Trap as needed:
With Compressor running, drain
moisture collected in Water Trap
by loosening nut at bottom of Drain
Valve. Moisture will be forced out.
IMPORTANT: Proper spraying technique
is ESSENTIAL to achieve good results.
1. Turn on Compressor’s Power Switch.
2. Press down on Airbrush Trigger to release air
from Nozzle. Slowly and gently draw back on
Trigger to release paint from Needle. The air
will atomize the paint and create a fine spray.
3. Continue to move Trigger back slowly
to achieve the consistency you
need for your spray technique.
4. Once you have achieved desired
consistency, you may fix the position
using Adjustment Screw.
Note: If Air Cap becomes clogged, move
Needle Chucking Guide back and forth.
5. Keep the distance from workpiece at about 3″
to 5″, depending on air flow and paint type.
6. For very fine detail work, you may decrease
the distance up to 1" from workpiece.
Note: The size of your spray pattern
will differ based on distance between
workpiece and Airbrush. The closer the
Airbrush is, the finer the pattern will be.
7. To avoid paint buildup, start moving Airbrush
before pressing Trigger.
When finished with the stroke, release
Trigger while still moving Airbrush. Doing this
will produce a smoother finish. Do not stop
moving Airbrush while spraying. If Airbrush
stops even briefly while spraying, paint can
build up and run down the workpiece.
CAUTION! Air hose fittings may get hot.
Allow fittings to cool before disconnecting,
or wear gloves to prevent burns.
8. When finished using the Compressor,
turn its Power Switch off. Release any
remaining air, then disconnect the Airbrush.
9. Perform maintenance on the
Compressor according to the
instructions on the following pages.
10. Clean Airbrush and Jar thoroughly
IMMEDIATELY after EVERY use, according
to instructions on the following pages.