SKU 65902/66742 For technical questions, please call 1-800-444-3353. Page 8
Blaster. Note: Use of quick coupler
is recommended, but not mandatory.
Note: Air ow, and therefore Soda Blaster
performance, can be hindered by
undersized air supply components.
The air hose must be long enough 3.
to reach the work area with enough
extra length to allow free movement
while working.
Close the in-line safety valve be-4.
tween the compressor and the Soda
Blaster.
Turn on the air compressor according 5.
to the manufacturer’s directions and
allow it to build up pressure until it
cycles off.
Adjust the air compressor’s output 6.
regulator so that the air output is
enough to properly power the Soda
Blaster, but the output will not exceed
the Soda Blaster’s maximum air pres-
sure at any time. Adjust the pres-
sure gradually, while checking the air
output gauge to set the right pressure
range. To do so, close Air Input ON/
OFF Valve (4). Pull out on the Quick
Disconnect Safety Valve (7) to stabi-
lize air pressure in the Storage Tank
(1).
If the Soda Blaster will not be used at 7.
this time, turn off and detach the air
supply, safely discharge any residual
air pressure, and release the throttle
and/or turn the switch to its off posi-
tion to prevent accidental operation.
Note: Residual air pressure should not be
present after the Soda Blaster is dis-
connected from the air supply. How-
ever, it is a good safety measure to
attempt to discharge the Soda Blaster
in a safe fashion after disconnecting
to ensure that the Soda Blaster is
disconnected and unpowered.