• Programmable reporting codes for system trouble situations: Low battery voltage”, Restore battery voltage”, AC power loss”, AC power
Restore”, Bell Trouble (upon disconnection, short circuit or overload on the Bell output), Bell trouble Restore” (Restore of disconnection or overload on
the Bell output), AUX output overload”, AUX output overload Restore”, System time and date Loss”, “System time and date Reprogrammed”,
Keypad lockout”;
• Cancellation of reporting to CS may be performed only by installer.
Upload/Download
• Several upload/download operations (using the EZcom C612&C816 Software):
- Uploading the system parameters from control panel onto PC;
- Downloading the programming of system parameters from PC onto the control panel (PC programming);
- Uploading the event LOG from the control panel into PC, log file that can be saved also in PDF format (see the Upload/Download software
user manual);
- System time and date setting by PC;
- System (or partitions) arming/disarming by PC;
- Zone bypassing by PC;
- PGM activation/deactivation by PC (only for PGM outputs defined as “mono-stable”, “bi-stable” or “clock timer” types);
- Online display of the system/partitions status and troubles;
- Real-time, online display of the bypassed, alarmed or open zones.
• Programmable callback function with up to 3 attempts, automatic or manually activation (manually activation may be performed by master user or
installer);
• 800-events LOG upload with display and save possibility and optionally reported to CS;
• Option of automatic answer to PC calls, either after double call” or after programmable number of rings;
• Manual activation of communication with PC (PC upload/download acceptance), performed by master user or installer;
Cancellation of PC to panel communication performed by master user or installer.
Zones
6/8 fully programmable zones on the main board, expandable to 12/16 zones using zone doubling feature or keypads’ zones, with single
or double EOL resistor, NO/NC contacts, tamper recognition and programmable as delayed, instant, follower, 24 hour burglary, fire, tamper,
panic, medical emergency, arming/disarming (“keyswitch” or “stay keyswitch”) or guardian round type;
• Cerber C816w give installer the option of choosing how many of the 16 zones controlled by panel are wireless. Any combination of wired and/or
wireless up to 16 zones can be done.
• 19 zone attributes, individually programmable as audible/silent alarm”, steady/pulsing siren”, “manual bypassing”, “auto shutdown”, forced
arming”, chime function activating”, “stay”, intellizone”, “sensor under test”, as well as individually selectable zone response time;
Zone bypassing (automatic from swinger shut-down” or caused by home arming, if the zones have the “stay” attribute activated - and manually
by the users);
• 2 real partitions which can be armed/disarmed independently from each other allowed by user rights;