EasyManua.ls Logo

Cerber C816 - Section [030] Partitions OPTIONS

Default Icon
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
[4] 4
enabled
*
disabled
Switch to “stay arming” if user doesn’t
exit
SwitchStayArm B Enable k4 Disable k4
[5] 5
enabled
*
disabled
Autoarming will be stay type
AutoarmType B Enable k5 Disable k5
[6] 6
enabled
*
disabled
“Force Autoarming”
ForceAutoarm B Enable k6 Disable k6
[7] 7
enabled
*
disabled No beeps and dings on “Stay Arming”
NoWarnStayExit B Enable k7 Disable k7
[8] 8
enabled
*
disabled “Timed Autodisarming”
TimedAutoDis B Enable k8 Disable k8
Note: The default programmed options are marked with *.
Press the [1] to [8] keys in order to turn the appropriate option enabled/disabled and the keypads will display activate/deactivate status of the corresponding options.
After setting these options, press [#] key to confirm. The keypad buzzer will sound 6 confirmation beeps and the panel exits the [030] programming section, waiting for a new
command to enter another section or [#] key to exit the main programming menu.
Note: If the 4
-th
option is enabled in this section, then the B partition switches to stay arming mode automatically after any regular arming (by user, by PC or by keyswitch), if the user doesn’t
leave the protected area through any entry/exit point during the exit delay.
Section [031] Telephone OPTIONS
While the system is within “main programming menu” select section [031] to establish the telephone options. The 1 to 4 options will be displayed according to the table below:
Key pressed
to toggle
option
KP-126Pz / KP-164Pz (LED keypads)
Description
KP16LCD / KP16LCDL (LCD keypads)
Zone
LED
ON OFF 1
st
line message
2
nd
line message
Enabled Disabled
[1] 1
*
Pulse dialing DTMF dialing Dialing mode of phone numbers
Dialing Pulse k1 DTMF k1
[2] 2
after “double
call
*
after number
of rings
Answer method to the remote calls
C612Answ 2call k2 No.of Rings k2
[3] 3
enabled
*
disabled
TLM option 1
TLMOpt1 Enable k3 Disable k3
4
enabled
*
disabled
TLM option 2
TLMOpt2 Enable k4 Disable k4
[5] 5
TBR21 Other standard
Compatibility with TBR21
communication standard
DTMFlevel TBR21 k5 others k5
[6] 6
1:2 1:1.5
Dialing pulse ratio
PulseRatio 1:2 k6 1:1.5 k6
Note: The default programmed options are marked with *.
Press the [1] to [6] keys in order to turn the appropriate option enabled/disabled and the keypads will display activate/deactivate status of the corresponding options.
After setting these options, press [#] key to confirm. The keypad buzzer will sound 6 confirmation beeps and the panel exits the [031] programming section, waiting for a new
command to enter another section or [#] key to exit the main programming menu.
Remarks:
1.
When the control panel is dialing any phone number, it will dial in pulse or DTMF mode, according to the way the respective option was set (OPT 1 is ON or OFF).
2. The control panel checks the dialing line tone, waiting 4 seconds for that. If it cannot detect the line tone, will dial “blind.. For the next call, the procedure will be repeated.
3. If “voice/sound dialer answers to the remote interrogation calls” and/or “panel answers to remote PC calls options are enabled, then the second option in this section establish the
way in which the control panel will automatic answer to the remote calls.
3.1 The control panel recognizes if the call is made by a modem for upload/download or is a voice call for current system status interrogation.
3.2 In case double call” option is set in this section the numbers of rings programmed in section [039] will no longer be considered.
3.3 If double call” option is set, then for control panel to answer to remote PC calls and/or to the remote interrogation calls, the following conditions should met the following
conditions:
- The first remote call of the panel must have at least 2 rings;
- The second remote call of the panel should occur after at least 10s since the first call ended, but not later than 60 seconds since the end of the first call, otherwise the second call will be
ignored. On the second call the control panel will automatically answer after the second ring.