31
[1] 1
*
enabled disabled Address 1 keypad assigned to partition B
Kpd1 ->B Yes k1 Not k1
[2] 2
*
enabled
disabled Address 2 keypad assigned to partition B
Kpd2 ->B Yes k2 Not k2
[3] 3
*
enabled
disabled Address 3 keypad assigned to partition B
Kpd3 ->B Yes k3 Not k3
[4] 4
*
enabled
disabled
Address 4 keypad assigned to partition B
Kpd4 ->B Yes k4 Not k4
*
enabled
disabled
Address 5 keypad assigned to partition B
Kpd5 ->B Yes k5 Not k5
[6] 6
*
enabled
disabled
Address 6 keypad assigned to partition B
Kpd6 ->B Yes k6 Not k6
[7] 7
*
enabled
disabled
Address 7 keypad assigned to partition B
Kpd7 ->B Yes k7 Not k7
[8] 8
*
enabled
disabled
Address 8 keypad assigned to partition B
Kpd8 ->B Yes k8 Not k8
After setting these options, press [#] key to confirm. The keypad buzzer will sound 6 confirmation beeps and the panel exits the [029] programming section, waiting for a new
command to enter another section or [#] key to exit the main programming menu.
Section [030] – Partitions OPTIONS
While the system is being within “main programming menu” select section [030] to establish the options for partition A. The 1 to 8 options will be displayed according to the table
below: (first part – partition A)
Key pressed
to toggle
option
KP-126Pz / KP-164Pz (LED keypads)
Description
KP16LCD / KP16LCDL (LCD keypads)
Zone
LED
ON OFF 1
st
line message
2
line message
Enabled Disabled
[1] 1
enabled
*
disabled “Timed Autoarming”
TimedAutoarm A Enable k1 Disable k1
[2] 2
enabled
*
disabled “Inactivity Autoarming”
InactAutoarm A Enable k2 Disable k2
[3] 3
*
enabled disabled Buzzer warnings during exit delays
Beeps on exit A Enable k3 Disable k3
[4] 4
enabled
*
disabled
Switch to “stay arming” if user doesn’t
exit
SwitchStayArm A Enable k4 Disable k4
[5] 5
enabled
*
disabled
Autoarming will be stay type
AutoarmType A Enable k5 Disable k5
[6] 6
enabled
*
disabled
“Force Autoarming”
ForceAutoarm A Enable k6 Disable k6
[7] 7
enabled
*
disabled No beeps and dings on “Stay Arming”
NoWarnStayExit A Enable k7 Disable k7
[8] 8
enabled
*
disabled “Timed Autodisarming”
TimedAutoDis A Enable k8 Disable k8
Note: The default programmed options are marked with *.
Press the [1] to [8] keys in order to turn the appropriate option enabled/disabled and the keypads will display activate/deactivate status of the corresponding options.
Note: If the 4
-th
option is enabled in this section, then the A partition switches to stay arming mode automatically after any regular arming (by user, by PC or by keyswitch), if the user doesn’t
leave the protected area through any entry/exit point during the exit delay.
After setting first set of options, press [#] key to confirm. The keypad buzzer will sound 3 beeps and will display next 1 to 8 options according to the table below:
(second part – partition B)
Key pressed
to toggle
option
KP-126Pz / KP-164Pz (LED keypads)
Description
KP16LCD / KP16LCDL (LCD keypads)
Zone
LED
ON OFF 1
st
line message
2
nd
line message
Enabled Disabled
[1] 1
enabled
*
disabled “Timed Autoarming”
TimedAutoarm B Enable k1 Disable k1
[2] 2
enabled
*
disabled “Inactivity Autoarming”
InactAutoarm B Enable k2 Disable k2
[3] 3
*
enabled disabled Buzzer warnings during exit delays
Beeps on exit B Enable k3 Disable k3