• Individually programmable exit and entry delay times for each partition – allowed by programming;
• Programmable alarm type: silent or audible and for audible alarms steady or pulsing;
• Individual siren timers for burglary and fire alarms;
PGM functions
• 2 programmable outputs (PGMs) on the main board, expandable to 8 PGMs using other modules, each with 39 options, such as: “Panic
alarm latch”, “Fire alarm latch”, “Medical emergency alarm latch”, “Latch on tamper alarm”, “Any alarm latch”, “Pulsing siren”, “Steady siren”, “silent
alarm” latch, “Follow system status” (ON while system is armed / OFF while system is disarmed), “Entry delay”, “Exit delay”, “System troubles”, “Clock
timer”, “Warning/confirmation pulses”, “Pulse after exit delay”, “Pulse on arming”, “Pulse on disarming”, “Courtesy light”, “Pulse on siren troubles”,
“Retriggerable mono-stable”, “Resetable mono-stable”, “Bi-stable” and “Pulse on alarm triggered by each 1 to 16 zones”;
Monitoring of system troubles
• Battery Voltage and AC power monitoring;
• Siren monitoring (upon disconnection, short circuit or overload);
• “AUX overload” monitoring;
• Option of telephone line monitoring (TLM).
Voice messages (synthesis sounds) Communicator
• Capability of response to the remote calls for system status interrogation (the system status -armed/disarmed/alarm/”AC power loss” – will be
reported by specific voice messages or by specific synthesis sounds);
• Programmable options of responses to the remote calls for system status interrogation, either after “double call” or after programmable
number of rings;
• Programmable option for automatic initiating reporting of the specific voice messages (or the specific synthesis sounds) to the “follow-me”
phone numbers, when several “alarm” and “AC power loss” events occur in the system;
• Phone line tone detection upon automatic initiating voice message reporting;
• Using the MPV-16/DTMF voice module, several voice messages can be recorded, as for voice zone descriptors (12/16 messages), system
(partitions) status, commands and voice message confirmations and guides. All these messages are used by panel upon remote interrogation
calls or to the “follow-me” phone numbers events reporting;
• In case of no MPV16/DTMF module, the panel will report upon remote interrogation calls or to the “follow-me” phone numbers synthesis sounds;
• Up to 4 “follow-me” phone numbers (for automatic control panel report on the telephone line of the “alarm” and “AC power loss” events, by specific
voice messages or by specific synthesis sounds);
RF remote control and/or proximity card operating (using Keyfob Module -01)
• Each user code can have one RF remote control transmitter (3 button keyfob – TX434) and/or one proximity card assigned;
• The keyfob can be used as a virtual keypad (transmitting commands, no confirmation on keyfob, just audio confirmation on keypads buzzer and keyfob
module buzzer, or on system sounders, by “ding” options programmed or visual confirmation using the keyfob module LAMP output) for