EasyManua.ls Logo

CFMoto CF500 - Battery and Regulator;Rectifier Service; Battery Service

Default Icon
254 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8. Battery, Charging System
Battery
Note:
Keep the ignition switch at OFF before operation.
Remove:
--Seat (2-3)
--Bolt1&Bolt2
--Battery fixing plate
--Battery cover
Loosen negative pole screw and disconnect negative
lead.
Remove positive pole cap and screw.
Disconnect positive lead.
Installation:
Reverse the removal procedure for installation.
Note:
¾ Apply clean lubricant grease to the pole after
installation.
¾ Install cap firmly on the positive pole after
installation.
Inspection:
Measure voltage between battery terminals, and check
test status.
Complete test: 12.8V
Insufficient test: <11.8V
Insufficient charge: Recharge
Note:
When recharging after normal charging, measure
the voltage between terminals after 30 minutes.
Measuring immediately after recharging will not gain
the correct test due to the sharp voltage changes
between the terminals.
Battery
Note:
Usually no hydrogen will be generated during charging
except when overcharged. Keep away from fires when
charging.
Charge according to the current and time specified on
the label of battery.
Remove battery from vehicle. (Refer to above content)
8-4

Related product manuals