55
Settings
GB
menu
sub-menu
parameter
description value
default setting
3
BOILER WITH TANK INTERNAL OR EXTERNAL AND SOLAR APPLIANCE CONNECTION
3 1
Entering access code 222 Turn the encoder clokwise to select
234 and press the MEnu button
3 2 SPECIAL SETTING
3 2 0
Anti-legionella function ON or OFF OFF This function avoids the formation
of the legionella bacterium wich
sometimes develops in pipes and
water tanks where the temperature
is included between 20 and 40°C.
If the storage temperature remains
more than 100 hours less than 59°C
and the function is enable, the
boiler is light aan and the storage
water is warmed up to 65°C during
30 minutes.
3 2 1 NOT PRESENT
3 2 2 NOT PRESENT
3 2 3
Collector delta temp pump ON from 0 to 30°C 8
Enable only with Clip-In solar connected
(option).
On the display, the symbol
3 2 4
Collector delta temp pump OFF from 0 to 30°C 2
3 2 5
Minimum collector temp pump ON from 10 to 90°C 30
2 2 6
Collector kick ON or OFF OFF
3 2 7
Recooling function ON or OFF OFF
3 2 8
Collector delta minimum function from 0 to 20 °C 10
3 2 9
Collector frost protection temperature from -20 to +5°C -20