User's manual
27
User's manual
GB
Setting the tank reduced and Comfort temperatures
For the production of domestic hot water, the Comfort and reduced
temperatures used to program the timer for the domestic hot wa-
ter can be set. The boiler controls the tank according to the desired
temperature.
Indirect Cylinder Temperature Setting
“Set Setpoint T
To set the temperature of the domestic water in the indirect cylinder,
proceed as follows
- Press the MENU/OK button; the menu 000 gure will ash.
- Turn the encoder until selecting menu
300 - “Solar and Indirect
Cylinder”.
- Press the MENU/OK button to access the sub-menus;
3
0
0
“General Settings” will ash.
- Press the MENU/OK button to access the sub-menus;
300
“Storage Setpoint T will ash.
- Press the MENU/OK button to modify the parameter.
- Turn the encoder to select the new value.
- Press the MENU/OK button to store the modication.
- Press the ESC button to exit the menu.
Domestic hot water button 9 is used for setting.
Domestic Water/Indirect Cylinder Reduced Temperature
Setting
“Storage Reduced T”
To set the reduced temperature for the domestic water, proceed as
follows:
- Press the MENU/OK button; the menu
000 gure will ash.
- Turn the encoder
until selecting menu 300 - “Solar &
Storage.
- Press the MENU/OK button to access the sub-menus;
3
0
0
“General Settings” will ash.
- Press the MENU/OK button to access the parameters;
300 will
ash.
- Turn the encoder
to select parameter 302 “Storage Reduced
T.
- Press the MENU/OK button to modify the parameter.
- Turn the encoder
to select the new value.
- Press the MENU/OK button to store the modication.
- Press the ESC button to exit the menu.
menu
sub-menu
parametri
description
“Display text” range
factory setting
3 SOLAR & STORAGE
3 0
GENERAL SETTINGS
3 0 0
Setting day temperature D.H.W/
storage
from 40 to
65 °C
60
3 0 1 NOT ACTIVE
3 0 2
Setting reduce temperature
D.H.W/storage
from 10 to
65 °C
35
MENU 3 - SOLAR & STORAGE
menu
sub-menu
parameter
description
“Display text”
range
factory
setting
4
ZONE1 PARAMETERS
4 0
SETPOINTS
4 0 0
Setting day temperature
Zone 1
“Zone1 T Day
from 16 to 30 (°C )
19
Only active when the BUS device is connected
4 0 1
Setting night temperature
Zone 1
“Zone1 T Night
from 16 to 30 (°C )
16
Only active when the BUS device is connected
4 0 2
Setting xed temperature Central Heating
“FIX Temp.
from
35
to
82 (°C)
70
Only active with thermoregulation set at xed temperature
5
ZONE2 PARAMETERS
5 0
SETPOINTS
5 0 0
Setting day temperature
Zone 2
“Zone2 T Day
from 16 to 30 (°C )
19
Only active when the BUS device is connected
5 0 1
Setting night temperature
Zona 2
“Zone2 T Night
from 16 to 30 (°C )
16
Only active when the BUS device is connected
5 0 2
Setting xed temperature Central Heating
“FIX Temp.
from
35
to
82 (°C)
70
Only active with thermoregulation set at xed temperature
MENU 4 - MENU 5
PARAMETRI ZONA 1 e 2

Other manuals for CHAFFOTEAUX NIAGARA C 25 CF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CHAFFOTEAUX NIAGARA C 25 CF and is the answer not in the manual?

CHAFFOTEAUX NIAGARA C 25 CF Specifications

General IconGeneral
BrandCHAFFOTEAUX
ModelNIAGARA C 25 CF
CategoryBoiler
LanguageEnglish

Related product manuals