User's manual
GB
INFO ( ) - display only
If the INfO button is pressed, a menu is accessed which enables the
data listed in the table below to be displayed.
The display scrolls through various information when the CH knob
is turned.
Press the Esc button to restore the normal display screen.
SRA Button
The SRA function enables boiler operation to be adapted to
environmental conditions and to the type of system it is installed
on.
Comfortable temperature is reached inside the room in the quickest
way possible, without wasting money, energy or eciency, while
substantially reducing the amount of wear experienced by the
components.
Your installer will advise you on the devices connectable
to the boiler and will program it according to the
system.
In normal boilers the water temperature inside the heating elements
is usually set to a high value (70-80°C), thereby ensuring eective
heating during the few really cold winter days. It then becomes
excessive on less cold days (of which there are many) more typical
of the autumn and winter seasons. This leads to excessive room
heating after the thermostat has been switched o, resulting in
energy waste and uncomfortable conditions inside the room.
The SRA function “takes control” of the boiler and selects the best
operating regime based on environmental conditions, external
devices connected to the boiler and the performance required. It
constantly decides at which power level to operate based on the
environmental conditions and the room temperature required.
Change of gas type
Our boilers are designed to function either with Natural Gas (meth-
ane) or L.P.G. gas. If you need to change from one gas to the other,
one of our Authorised Service Centres must be contacted to convert
the appliance.
Maintenance
Schedule an annual maintenance check-up for the boiler with a
competent person.
Correct maintenance always results in savings in the cost of running
the system.
Failure to arrange an annual service for the appliance will invalidate
the second year of the manufacturers guarantee.
Time of day - Hour
Heating circuit pressure (bar)
External temperature (°C)
-only with external sensor connected
Room temperature (°C)
-
only active when the BUS device is connected
D.H.W. Flow rate (l/m)
Set C.H. temperature (°C)
Set D.H.W. temperature (°C)
Month until next maintenance
Technical Assistance Centre telephone number and name
(only display if setted parameters 890)
D.H.W. comfort temperature (°C) - if activated
SRA Function
“enabled” or “disabled”
Storage temperature °C
only for boiler with storage tank