CSW24U / CSL24U
For technical questions on solar installations,
please contact LiftMaster Technical Support
800.528.2806
© 2016 LiftMaster All Rights Reserved
845 Larch Ave., Elmhurst, IL 60126
LiftMaster.com
LMGTCTSLGD 2/16
LiftMaster
®
Solar Gate Cycles
per Day
Reference Guide
LiftMaster Solar Gate Operators feature a best-in-class
power management system that delivers power when
needed most to operate the gate while minimizing
power consumption at all other times. Power is
provided to the gate operator via batteries. The
batteries are charged from a solar panel(s) connected
to the operator. The number of solar panels required
is determined by whether the application is for a single
or dual-gate, daily cycle rate, control board current
consumption by feature and accessory, and region
of the country.
Solar panel(s) must be located in an open area clear
of obstructions and shading for the entire day. Snow,
heavy fog or heavy rain affect solar panel performance
and charge rate. Solar panels should be cleaned
regularly to ensure proper operation. LiftMaster Gate
Operators utilizing the solar option in cold weather
climates where temperatures reach below -32°F (0°C)
for more than 2 consecutive weeks require 33Ah
batteries in lieu of standard 7Ah batteries. This is
due to the effect of cold weather on batteries and a
reduced number of hours of sunlight during the winter
months. (see back page for details)
LiftMaster Solar Gate Operators are engineered to have low idle current draw including radio
receiver to maximize battery life and solar performance. It is important to note, the following
environmental factors can adversely affect battery performance in solar applications.
· Cold temperature (below 32°F (0°C))
· Snow cover on solar panel
· Reduced hours of sunlight in winter months
In geographic areas that experience cold temperatures below 32°F (0°C) for more than two
weeks in addition to any of the factors listed above, the following steps can be taken to ensure
best performance:
· Replace the standard 7Ah batteries with 33Ah batteries. (For linear actuators, use the
optional XL control box model XLSOLARCONTU)
· In states adjacent to Canada and Canadian provinces, increase the angle of the solar panels
by an additional 15 degrees (60 degrees total). This will optimize the solar panels for the
winter months and reduce the buildup of snow and ice on the panels.
Important note: Daily cycle rate and standby time will be reduced by at least 50% when
temperatures reach extreme cold temperatures below -4°F (or -20°C) for periods of more than
two weeks.
For best performance during the winter months, snow and ice should be removed from the solar
panel, moving parts on the gate and gate operator. In addition all snow should be removed from
the path of the gate to prevent nuisance reversals.
If heavy amounts of snow are expected over several days, the manual disconnect may be
engaged and the gate left open to allow access and snow removal. Once the snow is removed,
simply reengage the manual disconnect to resume normal operation.
OPTIONAL POWER SUPPLY FOR COLD WEATHER APPLICATIONS
Gate Operator Optional Power Supply
LA500PKGU, LA412PKGU, LA400PKGU XLSOLARCONTU ((2) 33Ah batteries not included)
CSW24U, CSL24U (2) 33Ah batteries recommended in lieu of standard 7Ah batteries
RSW12U, RSL12U (1) 33Ah batteries recommended in lieu of standard 7Ah batteries
* Not Currently Offered in Accessory Line
7Ah
batteries
33Ah
batteries
7Ah
batteries
33Ah
batteries
7Ah
batteries
33Ah
batteries
5192011124 5
15 16 17
8922
20 14 16
7811
40 9102 3#NUM! #NUM!
60 45#NUM!#NUM! #NUM!#NUM!
5414825291
01
2
15 38 45 21 26
79
20 36 43 20 24
68
50 26 32 11 15 #NUM
!1
1001116#NUM! 2#NUM! #NUM!
578110 47 66 19 28
15 74 10643631
62
4
20 72 10441611
52
3
10042711532#NUM! 1
2001034#NUM! 2#NUM! #NUM!
597173 58 1052
44
4
15 92 16954101 21 41
20 90 16653991
93
9
10059131 25 67 #NUM
!1
3
250968 #NUM!14#NUM! #NUM!
CSW24U
Gate solar cycles per day
Zone 1
(6 Hrs Sunlight/Day)
Zone 2
(4 Hrs Sunlight/Day)
Zone 3
(2 Hrs Sunlight/Day)
10W* Solar Pane l
NOTE: Must Use 24V
Solar Panel
20W Solar Pane l
NOTE:20W would be
(2) 10W 12V panels in
seri es
40W Solar Pane l
NOTE: 40W would be
(2) 20W 12V pa nels in
seri es
60W* Solar Pane l
NOTE: Must Use 24V
Solar Panel
Total
System
Current
Draw (mA)
7Ah
batteries
33Ah
batteries
7Ah
batteries
33Ah
batteries
7Ah
batteries
33Ah
batteries
5262815176 6
15 22 24 12 13
33
20 20 22 10 11
12
40 12 14 34#NUM!#NUM!
60 57#NUM!#NUM! #NUM!#NUM!
5576734401
41
6
15 52 62 30 36 10 12
20 50 60 28 33
81
1
50 36 45 15 20 #NUM
!1
1001523#NUM! 3#NUM! #NUM!
5108 15265922
73
8
15 103147 60 87 23 34
20 100144 58 84 21 32
10058992144#NUM! 1
2001447#NUM! 3#NUM! #NUM!
5134 24081146 34 61
15 128234 76 1402
95
6
20 125231 73 1372
75
4
10082181 34 92 #NUM
!1
8
2501295#NUM! 20 #NUM!#NUM!
CSL24U
Gate solar cycles per day
10W* Solar Pane l
NOTE: Must Use 24V
Solar Panel
20W Solar Pane l
NOTE:20W would be
(2) 10W 12V panels in
seri es
40W Solar Pane l
NOTE: 40W would be
(2) 20W 12V pa nels in
seri es
60W* Solar Pane l
NOTE: Must Use 24V
Solar Panel
Zone 1
(6 Hrs Sunlight/Day)
Zone 2
(4 Hrs Sunlight/Day)
Zone 3
(2 Hrs Sunlight/Day)
Total
System
Current
Draw (mA)
LA500PKGU
LA412PKGU
LA400PKGU
CSW24U
CSL24U
RSW12U
RSL12U
Control Board Feature Current Draw (mA)
Main board with no radios learned 2.7
One or more LiftMaster
®
remote controls learned +1
MyQ
®
device or wireless dual-gate learned +2.4
Expansion board +11.1
Per loop detector LOOPDETLM (up to 3 loop detectors
can be plugged in to the expansion board) +3.8
Monitored Wireless Edge Kit (Model LMWEKITU receiver accepts up to (4) edge
transmitters and each transmitter accepts up to (2) wired edges for a total system
of (8) Monitored LiftMaster Edges, (1) receiver per gate operator.)
+12
Note: If the additional features on the expansion board are not used, it may be unplugged to conserve additional power draw (11mA)
Current consumption by control board feature 24V (CSW24U, CSL24U)
configurations. Add up current draw by feature and accessory to determine
total current draw.

Other manuals for Chamberlain CSW24U

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chamberlain CSW24U and is the answer not in the manual?

Chamberlain CSW24U Specifications

General IconGeneral
TypeSwing Gate Opener
Battery BackupYes
Smart Phone ControlYes
Motor TypeDC
Safety FeaturesObstruction detection
Remote ControlYes