Chapter 3 Using the 80H10323606A0 backplane
HDD Status indicators
The HDD indicators provide the HDD status as following table
Status
Blue
Green
Red
No present
Off
Off
Off
Offline
On
Blink for HDD
activity /access
(InFrame) indicating
Off
Idle
On
Off
Active
On
Off
Fail
On
On
Locate
On
4Hz blink
Rebuild
On
1Hz blink
Wide port status indicators
The wide port indicators provide the wide port connection status of connected and disconnected.
Status
Green
Red
Connected
Blink
OFF
Disconnected
OFF
ON
DIP Switch
The DIP switch allows user to change system settings
Refer to Buzzer Code
Refer to I
2
C Address setting
Function
DIP NO.
Default
ON
OFF
Fan 1
DIP1
On
Enable
Disable
Fan 2
DIP2
On
Enable
Disable
Fan 3
DIP3
On
Enable
Disable
Fan 4
DIP4
On
Enable
Disable
MB PWM
DIP5
On
Allows motherboard
control fan speed
Backplane control fan speed
Temp alarm
DIP6
On
Alarm at 55C
Alarm at 65C
ACC LED mode
DIP7
On
By SGPIO
By HDD PIN 11
Buzzer
DIP8
On
Enable
Disable