Page 10SKU 66604 For technical questions, please call 1-800-444-3353.
3-Prong, duplex NEMA 120 volt Outlet Socket (8) - Qty 2a.
3-Prong, NEMA Twistlock, 120 volt Outlet Socket (10)b.
4-Prong, NEMA Twistlock, 240/120 volt Outlet Socket (10B)c.
WARNING! Connect tools and equipment only to the Outlet Socket (120 volt or
240 volt) that is compatible with the electrical characteristics and rated capacities
of the tools and equipment being used. (See Figure A.)
Circuit Breakers (3, 5): 3. The Generator features ve Circuit Breakers to protect
the unit from overloading.
Onea. 20 Amp Circuit Breaker controls the 3-Prong, 120 volt Outlet Socket (8).
Oneb. 30 Amp Circuit Breaker controls the 3-Prong, Twistlock, 120 volt Outlet
Socket (10).
Twoc. 30 Amp Circuit Breakers control the 4-Prong, Twistlock, 240/120 volt Outlet
Socket (10B).
Oned. In-Line Circuit Breaker to protect the Engine’s Starter (83A).
Should any of the four Circuit Breakers “trip”, the Engine will automatically shut
down. In this event, unplug all loads from the Generator. Allow the Generator to
cool down. Then, press the tripped Circuit Breaker and restart the Engine. (See
Figure A.)
Positive and Negative DC Outlet Terminals and Fuse (6): 4. 12 VDC outlet termi-
nal set provides a power source for 12 volt DC items.
Voltmeters (7): 5. The Generator features two Voltmeters which provide readings
of voltage output depending on which of the three Outlet Sockets (8, 10, 10B) are
being used. (See Figure A.)
Grounding Terminal (9): 6. Prior to each use, always connect a ground wire (not
included) to the Grounding Terminal to properly ground the Generator.
(See Figure C, page 11.)
BATTERY INSTALLATION
The Engine of the Generator may be started manually or electrically.1.
To use the Engine’s electric start capability, a Battery (45, not included) must rst 2.
be installed. The type and size Battery required is: 12 volt DC, 7-1/4” long by 3”
wide. (See Figure B, next page.)
Locate the factory pre-installed Battery Guard Plate (44) and Battery Tray (48) 3.
beneath the Control Panel of the Generator. (See Figure B.)
Slide the Battery into the Battery Guard Plate (44) with the Battery’s terminals 4.
facing outward and with the Battery’s negative (--) terminal facing left. (See Figure B.)
REV 09l