CHIGO CAC FCU
Fault codes table(1)
Probe of Room temp.sensor
goes wrong
TIMER lamp flashes at the speed of
5 Hz
The system will recover
normal operation once
faults are eliminated
Probe of Evaporator sensor
goes wrong
RUN lamp flashes at the speed of 5
Hz
Probe of Condenser sensor
goes wrong
Defrost lamp flashes at the speed of
5 Hz
Water fulfilled protection
Warning light flashes at the speed
of 5 Hz
Both defrost lamp and warning light
flash at the speed of 5 Hz
Both RUN lamp and defrost lamp
flash at the speed of 5 Hz
The display should be
cleared up by manual
EEPROM Communication
fault
Both RUN lamp and TIMER lamp
flash at the speed of 5 Hz
Forced cooling indication
Both RUN lamp and warning light
flash at the speed of 5 Hz
The display will be
cleared up after exiting
the operating mode.
Anti-cold wind indication in
heating mode
Defrosting preheating is ON
The display will be
cleared up after exiting
the operating mode.