EasyManua.ls Logo

Chikusui Canycom CM 221 - Cutter Blade Case

Chikusui Canycom CM 221
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 33 -
Seat Cover
Rod
Cutter blade case
Oil drain plug Oil filler plug
7.4.4 Cutter Blade Case
Maintenance
Inspection
1. Park machine on a horizontal surface.
2. Open the seat cover, and support it rmly with the rod to
prevent it from closing.
3. Check the oil level in the oil level gauge.
If it is low, add more designated oil.
Adding
1. Remove the oil ller plug from the cutting blade case.
2. Pour the specified oil into the lubrication port.
Inspection
1. Prepare a suitable container to collect drained oil.
5313M-0704-060
5313M-0704-070
5313M-0704-080
Avoid contact with high temperature oil to avoid burns.
2. Remove the drain plug and drain oil.
3. Replace the drain plug.
4. Open the oil filler plug and add proper amount of desig-
nated oil.
5. Replace the oil filler plug firmly.
Dispose of the drained oil properly.