EasyManua.ls Logo

Chikusui Canycom CM 221 - Adding Water (Battery Fluid)

Chikusui Canycom CM 221
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 35 -
7.6 Adding Water (Battery Fluid)
Flammable gas is generated by the battery. Keep open flames away from battery.
Open flames may cause battery explosion.
• Battery fluid contains sulfuric acid which may cause burns. Avoid fluid contact with
skin or clothes. In case of contact, immediately remove affected clothes and clean
the affected skin.
• Before checking or removing the battery, always stop engine and turn “OFF” the main
switch.
Inspection
1. Park machine on a horizontal surface.
2. Check the electrolyte level. If it is low, remove the head
lamp cover, and replenish electrolyte.
Proper battery fluid level: between Upper and Lower
reference lines
Battery fluid: Distilled water
Replacement
1. Check the electrolyte level. If it is low, remove the head
lamp cover, and replenish electrolyte.
Battery
Headlamp cover
Battery
Upper level
Lower level
• Always remove the battery from the machine before charging it. Failure to do this will
cause damage to electrical components and to the wiring.
• When connecting cables to the battery, use the correct (+) and (-) terminals.
Reversing connections will blow the fuse and prevent charging.
• For safety, always disconnect the (-) terminal first, and connect the (+) terminal first.
Disconnecting or connecting in the opposite order may cause a short circuit.
• When reinstalling the battery, connect the (+) and (-) to their original positions. Avoid
contact between terminals and other surrounding parts
Maintenance
5316M-0706-010
5313M-0706-020