NVF5 Series User Manual Chapter 5 Simple Parameter Menu and
Commissioning Process
F0.20
Parameter
Factory
Default
◎
0:No Effect
1:Fault Log Clear
2:Set to Factory Default(
Except
Motor NP
Parameters and
Parameter F7.11)
3 :
Reset Custom Parameter
Group to Factory Default(Except
Motor NP Parameters and
Parameter F7.11)
4:All Parameter Reset to Factory
Default
5:Back Up Parameters
6:Using Back Up Parameters
7:Saving Back Up Parameters
Note:
Only when you are using
backup parameters,backup
parameter are able to be
saved.Otherwise when power off
then re-power the inverter,except
the updated parameters other
parameters are always initial
value.
0
F2.00 Motor Type ○
0:AC Induction Motor
1:Reserve
2:Reserve
0
F2.01
Motor NP
Power
◎
(0.1 ~ 1000.0) kW
Depend on
motor type
F2.02
Motor NP
Voltage
◎
0V ~ Inverter Rated Voltage
Depend on
motor type
F2.03
Motor NP
Current
◎
(0.1~1000.0)A
Depend on
motor type
F2.04
Motor NP
Frequency
◎
0.01Hz ~ F0.07
Depend on
motor type
F2.05 Motor Poles ◎
2 ~ 24
4
F2.06
Motor NP
RPM
◎
(0~60000)rpm
1430rpm
F2.22
Motor Auto
Tuning
◎
0:No Operation
1:Static Tune
2:Rotate Tune
0