Chore-Tronics Model 16 & 8 Control Initial Setup
11
MT1554A
VAR FAN 1 & 2
1, 2 ,3, and 4 are the onl
y
values that can be edited. If the variables
are to function independentl
y
of each other, the “On” for variable 2
has to be set at 2.5°F above the “On” for variable 1.
If the “on” for both variables are the same, then the
y
will function
identicall
y
.
Types of Timers
There are two types of timers.
1. The first type is only used for COOL outputs. It modulates (turns on and off) a
COOL output above the COOL output’s “on temperature”.
2. The second type of timer is used on EXH FAN, STIR FAN, TUN FAN (Model
16) and VAR FAN 1 outputs. It modulates an output below these output’s “on
temperature”.
Key
Description
1
Minimum Speed 1
2
Minimum Speed 2
3
*Variable Fan 1 – on
4
*Variable Fan 2 – on
5
2.5° Fahrenheit – minimum allowed
6
.5° Fahrenheit – fixed
7
Variable Fan #1 – Full Speed
8
Variable Fan #2 – Full Speed
9
Increase Temperature
*See
Outputs-Temperatures
BUTTON 3