Programmable AC Source 61601/61602/61603/61604 User’s Manual
7.6.2.7 SYSTEM Sub-system
SYSTem
: ERRor?
: VERSion?
: LOCal
: REMote
SYSTem : ERRor?
Description : This command queries the error string of the command parser.
Query Syntax : SYSTem : ERRor?
Parameters : NONE
Return Parameters : Response error string:
No Error
Data Format Error
Data Range Error
Too Many Errors
Execution Error
SYSTem : VERSion?
Description : This query requests the AC source to identify itself.
Query Syntax : SYSTem : VERSion?
Parameters : NONE
Return Parameters :
SYSTem : LOCal
Description : This command can only be used under the control of RS-232C.
If SYST : LOC is programmed, the AC source will be set in the
LOCAL state, and the front panel will work.
Query Syntax : NONE
Parameters : NONE
Return Parameters : NONE
SYSTem : REMote
Description : This command can only be used under the control of RS-232C.
If SYST : REM is programmed, the AC source will be set in the
REMOTE state, and the front panel will be disabled except the
“<PAGE/EXIT> key.
Query Syntax : NONE
Parameters : NONE
Return Parameters : NONE
7.7 Command Summary
Common Commands
* CLS Clear status
* ESE<n> Standard event status enable
* ESE? Return standard event status enable
* IDN? Return the AC source identification
* RCL<n> Recall the AC source file
* RST Reset the AC source to the initial states