    Molly CervantesAug 15, 2025
    What to do if Chroma Power Supply shows OVER CURRENT protection (OCP)?
    • G
      gphillipsAug 16, 2025
      If the Chroma Power Supply indicates an OVER CURRENT protection (OCP) fault, it means the output current exceeds the specified limit or the set I LIMIT. To resolve this, remove the overload connected to the power supply or increase the I LIMIT setting.
  • L
    levinejulieAug 18, 2025
    What to do if Chroma Power Supply shows OVER POWER protection (OPP)?
    • S
      sean59Aug 19, 2025
      If your Chroma Power Supply displays an OVER POWER protection (OPP) message, it signifies that the output power is beyond its specification. To fix this, either decrease the output voltage or remove the excessive power draw from the connected load.
  • J
    jacksonmarcusAug 21, 2025
    What to do if Chroma 61605 Power Supply shows OUTPUT SHORT protection?
    • A
      Alex WilliamsAug 21, 2025
      If the Chroma Power Supply shows an OUTPUT SHORT protection error, it indicates a short circuit at the output or a reverse current flow. To resolve this: 1. Remove the short circuit. 2. Disconnect the load.
  • K
    Kevin LarsenAug 25, 2025
    What to do if Chroma Power Supply shows OVER TEMP protection (OTP)?
    • C
      Connor WilsonAug 25, 2025
      If the Chroma Power Supply displays an OVER TEMP protection (OTP) warning, it means the unit is overheating. This could be due to: 1. High ambient temperature: Ensure the unit is operated within a 0 ~ 40°C environment. 2. Obstructed airflow: Clear any blockages from the air vents to allow proper ventilation.
  • M
    Matthew BauerAug 27, 2025
    What to do if Chroma 61605 Power Supply shows INPUT FAIL protection (UVP)?
    • K
      Kylie Taylor DDSAug 27, 2025
      If the Chroma Power Supply shows an INPUT FAIL protection (UVP) message, it means the AC source line input voltage is either too low or too high. You should measure the input voltage and adjust it if it's outside the specified range.
  • D
    Darin SmithAug 30, 2025
    Why is Chroma 61605 Power Supply output distorted?
    • C
      Carrie LittleAug 30, 2025
      The distorted output from the Chroma Power Supply can be caused by: 1. AC source voltage being too low: Try programming a higher output voltage. 2. Rectified load being too large at high frequency: Reduce the load or lower the output frequency.
  • M
    mcmillanisaacSep 2, 2025
    What to do if Chroma Power Supply shows OUTPUT OVP protection?
    • Q
      qsmithSep 2, 2025
      If the Chroma Power Supply displays an OUTPUT OVP protection message, it could be due to: 1. Remote sense being open: Connect the output to the remote sense terminals. 2. Output voltage peak exceeding the range: Check the settings of Vac and Vdc on the MAIN PAGE.
  • M
    Megan GeorgeSep 5, 2025
    What to do if Chroma 61605 Power Supply shows INT _ AD protection?
    • T
      Thomas ReyesSep 5, 2025
      If the Chroma Power Supply shows an INT _ AD protection message, it may be due to: 1. Line input voltage cycle dropout: Check the stability of the input voltage. 2. Instant over current of output: Remove the load. If the protection status persists, it may indicate damage to the AD power stage, and you should consult the dealer for assistance.
  • C
    Chad WilliamsSep 8, 2025
    What to do if Chroma 61605 shows INT _ DD protection?
    • D
      Daniel HarrisSep 8, 2025
      If the Chroma Power Supply shows an INT _ DD protection message, it may be due to: 1. Line input voltage cycle dropout: Check the stability of the input voltage. 2. Instant over current of output: Remove the load. If the protection status persists, it may indicate damage to the DD power stage, and you should consult the dealer for assistance.
  • H
    hbishopSep 12, 2025
    How to fix poor measurement of V, I on Chroma 61605?
    • L
      Lori NielsenSep 12, 2025
      Poor voltage and current measurements on the Chroma Power Supply can be caused by the aging of internal components, leading to deviations in their characteristics. Periodic calibration is required to maintain accuracy.

Chroma 61605 Specifications

General IconGeneral
BrandChroma
Model61605
CategoryPower Supply
LanguageEnglish

Related product manuals