EasyManuals Logo

Chroma 62000H Series User Manual

Default Icon
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #201 background imageLoading...
Page #201 background image
Remote Operation
5-35
5.6.2.4 FETCH Subsystem
1. FETCh:VOLTage?
Description: It measures the output of Power Supply and returns real time
voltage.
Query Syntax: FETCh:VOLTage?
Return Parameter: <NRf+> [Unit Volt]
Query Example: FETC:VOLT?
Return Example: 9.983100e+00
2. FETCh:CURRent?
Description: It measures the output of Power Supply and returns real time
current.
Query Syntax: FETCh:CURRent?
Return Parameter: <NRf+> [Unit Amp]
Query Example: FETC:CURR?
Return Example: 2.000000e-04
3. FETCh:POWer?
Description: It measures the output of Power Supply and returns real time power.
Query Syntax: FETCh:POWer?
Return Parameter: <NRf+> [Unit Amp]
Query Example: FETC:POW?
Return Example: 5.000000e+03
4. FETCh:STATus?
Description: It returns the status code of Power Supply’s state.
Query Syntax: FETCh:STATus?
Return Parameter: <Arg1><,><Arg2><,><Arg3>
<Arg1>: return warning message 0~65535, 0: no warning, use
binary for the rest and identify the cause of error.
BIT 0: OVP
BIT 1: OCP
BIT 2: OPP
BIT 3: Remote Inhibit
BIT 4: OTP
BIT 5: FAN_LOCK
BIT 6: SENSE FAULT
BIT 7: SERIES FAULT
BIT 8: Reserved
BIT 9: AC FAULT
BIT 10: FOLD Back CV to CC
BIT 11: FOLD Back CC to CV
BIT 12: Reserved
BIT 13: Reserved
BIT 14: Reserved
BIT 15: Reserved
<Arg2>: ON|OFF output status at present
<Arg3>: CV or CC status at present