EasyManua.ls Logo

Chroma 63630-80-60 User Manual

Default Icon
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Chroma 63630-80-60 and is the answer not in the manual?

Chroma 63630-80-60 Specifications

General IconGeneral
BrandChroma
Model63630-80-60
CategoryPower Supply
LanguageEnglish

Summary

Safety Summary

Local Operation

Front Panel Keys & Indicators

Details the front panel keys and indicators of the mainframe and load modules for operation.

Setting Operation Mode of Static Load

Guides on setting the operational modes (CC, CR, CV, CP, CZ) for static load operations.

Setting Operation Mode of Dynamic Load

Details how to set up and operate the electronic load in dynamic load modes.

Setting the Configuration

Explains the initial setup and configuration parameters for the electronic load system.

General Information

Specifications

Lists detailed technical specifications for the 63600-5 and 63601-5 mainframes.

Installation

Installing the Modules

Guides on the procedure for installing load modules into the mainframe, emphasizing anti-static practices.

Installing the Mainframe

Covers the process of installing the mainframe, including environmental and ventilation requirements.

Application Connection

Explains how to connect the electronic load for various application scenarios, including load and remote sensing.

Operation Overview

Front Panel Description

Describes the front panel layout, including displays, keys, and indicators of the mainframes.

Rear Panel Description

Details the rear panel connectors and features of the mainframes for connectivity and cooling.

Local/Remote Control

Explains the difference between local and remote control modes and how to switch between them.

Constant Current Mode

Details the Constant Current (CC) mode, including current ranges, static, and dynamic load operations.

Dynamic Load Mode

Explains the operation of the dynamic load mode, including parameter setup for levels, slew rates, and timing.

Constant Resistance Mode

Describes the Constant Resistance (CR) mode, covering resistance programming and voltage/current ranges.

Constant Voltage Mode

Details the Constant Voltage (CV) mode, including voltage programming and current limit settings.

Constant Power Mode

Explains the Constant Power (CP) mode, covering power programming and slew rate levels.

Constant Impedance Mode

Describes the Constant Impedance (CZ) mode, including parameter settings for R, L, and C.

Protection Features

Lists the built-in protection features, including over-current, over-power, and over-temperature protection.

Remote Operation

Introduction to Programming

Introduces basic concepts of programming the electronic load using SCPI commands.

Language Dictionary

Provides a comprehensive dictionary of commands and subsystems for remote programming.

Status Reporting

Verification

CC Mode Verification

Verifies if current programming and readings in CC mode are within specifications.

CR Mode Verification

Verifies if resistance programming in CR mode is within specifications.

Related product manuals