General safety precautions to be observed during operation, service, and repair of the instrument.
Lists AC input range, fuse, frequency, VA, weight, and dimensions for mainframes.
Procedure for performing the initial self-test after powering on the load.
Details the five operational modes: CC, CR, CV, CP, and CZ, and their parameter handling.
Explains operation in CC mode, including current ranges and static/dynamic load modes.
Details programming 2 load levels, durations, slew rates, and repeat times for dynamic loading.
Explains operation in CR mode, including voltage ranges and resistance levels.
Details operation in CV mode, including voltage ranges and current limit settings.
Explains operation in CP mode, including power ranges and slew rate settings.
Details operation in CZ mode, covering series resistance, inductance, parallel capacitance, and resistance.
Details over current, over power, over temperature, and reverse voltage protection features.
Covers setting operation modes: CC, CR, CV, CP, and CZ for static load applications.
Instructions on how to select operational modes (CC, CR, CV, CP, CZ) using the MODE key.
Details on setting current ranges, states (A/B), current levels, and slew rates in CC mode.
Guide to setting resistance ranges, states (A/B), resistance levels, and slew rates in CR mode.
Instructions for setting voltage ranges, states (A/B), voltage levels, and current limits in CV mode.
Details on setting power ranges, states (A/B), power levels, and slew rates in CP mode.
Guide to setting CZ parameters: CL, RL, Rs, and slew rate in CZ mode.
Instructions to set the operation mode to CC for dynamic load.
Details on setting current levels, periods (T1, T2), slew rates, and repeat times in dynamic load.
Basics of programming, including command structure, data formats, and syntax.
Provides subsystems and commands for operating the load remotely.
Lists specific GPIB commands grouped into subsystems like ABORT, ADVANCE, CHANNEL, CONFIGURE, etc.
Commands for setting current parameters: DYNamic (L1, L2, REPeat, RISE, FALL, SWEep), STATic (L1, L2, RISE, FALL).
Commands to retrieve measurements: VOLTage, CURRent, POWER, AH, WH, STATUS, TIME.
Covers performance tests for CC, CR, CV, and CP modes.
Verifies current programming and readings in CC mode against specifications.
Procedure to check current readings in high range CC mode using DMM and shunt resistor.
Procedure to check current readings in medium range CC mode using DMM and shunt resistor.
Procedure to check current readings in low range CC mode using DMM and shunt resistor.
Verifies resistance programming and readings in CR mode against specifications.
Procedure to check resistance readings in high ohm range CR mode.
Procedure to check resistance readings in medium ohm range CR mode.
Procedure to check resistance readings in low ohm range CR mode.
Verifies voltage programming and readings in CV mode against specifications.
Procedure to check voltage readings in high range CV mode using DMM.
Procedure to check voltage readings in medium range CV mode using DMM.
Procedure to check voltage readings in low range CV mode using DMM.
Verifies current programming and readings in CP mode against specifications.
Procedure to check power readings in high range CP mode using DMM.
Procedure to check power readings in medium range CP mode using DMM.
Procedure to check power readings in low range CP mode using DMM.