Local Operation
3. Press the direction key ( ◄, ► ) or rotate the rotary knob to choose “SINGLE”, then press
ENTER.
4. Press CC, CR, CP or RLC/DC RECT to return to the mode that the users want to use.
For all AC Loads set to parallel mode, regardless of whether it is a Master or
Slave unit, to operate as a single unit, the operation mode must be set as
single mode. To return the Master unit to single mode, the steps are the
same as described above for the Slave unit.
PHASE SELECT only be displayed in A1. PHASE SELECT can set to A+B+C, A, B, C, this
item is for changing setting value of each phase. When A+B+C is selected, if I
set
, CF, PF,
Ip(max) changed thus A, B, C three phases will be changed at the same time. When A is
selected, if I
set
, CF, PF and I
p
(max) are changed thus only A phase will be changed. Similarly,
when B is selected, if I
set
, CF, PF and I
p
(max) are changed thus only B phase will be changed.
When C is selected, if I
set
, CF, PF and I
p
(max) are changed thus only C phase will be
changed.