EasyManua.ls Logo

Chroma 63802 - 8.6.2.3 Power Measurement

Default Icon
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programmable AC/DC Electronic Load 63800 Series Operation & Programming Manual
8-8
Example : MEAS:CURR:CRES?
MEASure[:SCALar]:CURRent:PEAK:NEGative?
FETCh[:SCALar]:CURRent:PEAK:NEGative?
Description: Return the negative peak current measured at the input of electronic load.
Query Syntax : MEASure[:SCALar]:CURRent:PEAK:NEGative?
FETCh[:SCALar]:CURRent:PEAK:NEGative?
Response Parameter: <NR2>
Example : MEAS:CURR:PEAK:NEG?
MEASure[:SCALar]:CURRent:PEAK:POSitive?
FETCh[:SCALar]:CURRent:PEAK:POSitive?
Description: Return the positive peak current measured at the input of electronic load.
Query Syntax : MEASure[:SCALar]:CURRent:PEAK:POSitive?
FETCh[:SCALar]:CURRent:PEAK:POSitive?
Response Parameter: <NR2>
Example : MEAS:CURR:PEAK:POS?
8.6.2.2 Frequency Measurement
MEASure | FETCh
[:SCALar]
:FREQuency? Return the output frequency
MEASure[:SCALar]:FREQuency?
FETCh[:SCALar]:FREQuency?
Description: Return the output frequency in Hertz.
Query Syntax : MEASure[:SCALar]:FREQuency?
FETCh[:SCALar]:FREQuency?
Response Parameter: <NR2>
Example : MEAS:FREQ?
8.6.2.3 Power Measurement
MEASure | FETCh
[:SCALar]
:POWer
:[REAL] ? Return real power
:AMPLitude
:MAX? Return peak power
:APParent? Return VA
:PFACtor? Return power factor
:REACtive? Return the reactive power
MEASure[:SCALar]:POWer[:REAL]?
FETCh[:SCALar]:POWer[:REAL]?
Description: Return the true power in Watts (W).
Query Syntax : MEASure[:SCALar]:POWer[:REAL]?
FETCh[:SCALar]:POWer[:REAL]?
Response Parameter : <NR2>

Table of Contents

Related product manuals