Using Remote Control
Separator 1: <NR2>;<NR2><RMT>
Example: none
[ CALCulate : ] COMParator : LIMit : IPK- 66201 | 66202
Description: This command sets upper and lower boundaries of negative peak current in
GONG mode.
Setting Syntax:
COMParator:LIMit:IPK-<space><NR2>,<NR2><PMT>
Setting Parameters: <NR2>,
66201: 0.000 ~ 9.999
66202: High shunt: 0.00 ~ 99.99
Low shunt: 0.000 ~ 9.999
Query Syntax: COMParator:LIMit:IPK-?<PMT>
Response Parameters: <NR2>,
66201: 0.000 ~ 9.999
66202: High shunt: 0.00 ~ 99.99
Low shunt: 0.000 ~ 9.999
Header on: :COMPARATOR:LIMIT:IPK-<space><NR2>,<NR2><RMT>
Header off: <NR2>,<NR2><RMT>
Separator 0: <NR2>,<NR2><RMT>
Separator 1: <NR2>;<NR2><RMT>
Example: none
[ CALCulate : ] COMParator : LIMit : IS 66202
Description: This command sets upper and lower boundaries of inrush current in GONG
mode.
Setting Syntax:
COMParator:LIMit:IS<space><NR2>,<NR2><PMT>
Setting Parameters: <NR2>,
66201: 0.000 ~ 9.999
66202: High shunt: 0.00 ~ 99.99
Low shunt: 0.000 ~ 9.999
Query Syntax: COMParator:LIMit:IS?<PMT>
Response Parameters: <NR2>,
66201: 0.000 ~ 9.999
66202: High shunt: 0.00 ~ 99.99
Low shunt: 0.000 ~ 9.999
Header on: :COMPARATOR:LIMIT:IS<space><NR2>,<NR2><RMT>
Header off: <NR2>,<NR2><RMT>
Separator 0: <NR2>,<NR2><RMT>
Separator 1: <NR2>;<NR2><RMT>
Example: none
[ CALCulate : ] COMParator : LIMit : CFI 66201 | 66202
Description: This command sets upper and lower boundaries of current crest factor in GONG
mode.
Setting Syntax:
COMParator:LIMit:CFI<space><NR2>,<NR2><PMT>
5-29