Using Remote Control
[ CALCulate : ] COMParator : LIMit : VA 66201 | 66202
Description: This command sets upper and lower boundaries of apparent power in GONG
mode.
Setting Syntax:
COMParator:LIMit:VA<space><NR2>,<NR2><PMT>
Setting Parameters: <NR2>, 0.00 ~ 9999.0
Query Syntax: COMParator:LIMit:VA?<PMT>
Response Parameters: <NR2> , 0.00 ~ 9999.0
Header on: :COMPARATOR:LIMIT:VA<space><NR2>,<NR2><RMT>
Header off: <NR2>,<NR2><RMT>
Separator 0: <NR2>,<NR2><RMT>
Separator 1: <NR2>;<NR2><RMT>
Example: none
[ CALCulate : ] COMParator : LIMit : VAR 66201 | 66202
Description: This command sets upper and lower boundaries of reactive power in GONG
mode.
Setting Syntax:
COMParator:LIMit:VAR<space><NR2>,<NR2><PMT>
Setting Parameters: <NR2>, 0.00 ~ 9999.0
Query Syntax: COMParator:LIMit:VAR?<PMT>
Response Parameters: <NR2> , 0.00 ~ 9999.0
Header on: :COMPARATOR:LIMIT:VAR<space><NR2>,<NR2><RMT>
Header off: <NR2>,<NR2><RMT>
Separator 0: <NR2>,<NR2><RMT>
Separator 1: <NR2>;<NR2><RMT>
Example: none
[ CALCulate : ] COMParator : LIMit : FREQ 66201 | 66202
Description:
This command sets upper and lower boundaries of frequency in GONG mode.
Setting Syntax:
COMParator:LIMit:FREQ<space><NR1>,<NR1><PMT>
Setting Parameters: <NR1>, 0 ~ 9999
Query Syntax: COMParator:LIMit:FREQ?<PMT>
Response Parameters: <NR1> , 0 ~ 9999
Header on: :COMPARATOR:LIMIT:FREQ<space><NR1>,<NR1><RMT>
Header off: <NR1>,<NR1><RMT>
Separator 0: <NR1>,<NR1><RMT>
Separator 1: <NR1>;<NR1><RMT>
Example: none
[ CALCulate : ] COMParator : LIMit : ENEG 66202
Description: This command sets upper and lower boundaries of energy in GONG mode.
Setting Syntax:
COMParator:LIMit:ENEG<space><NR1>,<NR1><PMT>
Setting Parameters: <NR1>, 0 ~ 9999
Query Syntax: COMParator:LIMit:ENEG?<PMT>
Response Parameters: <NR1> , 0 ~ 9999
Header on: :COMPARATOR:LIMIT:ENEG<space><NR1>,<NR1><RMT>
Header off: <NR1>,<NR1><RMT>
Separator 0: <NR1>,<NR1><RMT>
5-31