EasyManua.ls Logo

CIAT V30 User Manual

CIAT V30
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation
Operation
Commissioning
Maintenance
10 - 2011
NA 07.108 D
V30
Question and Answer IconNeed help?

Do you have a question about the CIAT V30 and is the answer not in the manual?

CIAT V30 Specifications

General IconGeneral
BrandCIAT
ModelV30
CategoryThermostat
LanguageEnglish

Summary

General Information

CIAT V30 Control Overview

Introduction to the V30 control for air conditioning terminal units.

Operation and Controls

Operating Instructions

How to use the dial for setting temperature and fan speeds.

Setting Setpoint Temperature

Adjusting hot and cold setpoints via dial and modes.

Setting Fan Speed

Manual fan speed selection and electric heating impact.

Neutral Zone Fan Operation

Fan behavior in neutral zone and periodic ventilation.

Post Ventilation Safety Period

2-minute fan operation after exiting modes or stopping.

Summer/Winter Changeover

Automatic or remote switching between heating and cooling modes.

External Switch for Economy/Frost Protection

Using an input for remote economy or frost protection.

Air Temperature Measurement

Methods for measuring air temperature using sensors.

Water Temperature Measurement

How to measure water temperature using a sensor.

Changeover Sensor Operation Logic

How the changeover sensor determines hot, cold, or neutral water.

Switch Parameter Settings

DIP switch configuration for various system applications.

Switch Configuration Details

Specific switch functions like neutral zone and window contact input.

Reconfiguring Built-in V30 Switches

Step-by-step guide for adjusting switches on built-in units.

Application Details

Application Settings and Modes

Mapping switch settings to applications and comfort/heating modes.

Application Details (Continued)

Further mapping of switch settings, applications, and modes.

Electric Heater Management

Control by Air (Applications B, C, D)

Electric heater stage control logic for air applications.

Control by Water (Applications G, H, I)

Electric heater stage control logic for water applications.

Unit Installation

Mounting and Electrical Connection

Instructions for physical mounting and electrical wiring of the unit.

Technical Specifications

Key technical data including power, current, and setpoints.

LED Operation and Alarms

Understanding V30 status LEDs and alarm indications.

Flush-mounted and Wall-mounted Unit Details

Physical dimensions and mounting specifics for unit types.

Tests and Warranty Information

Appliance testing procedures and warranty conformity.

Related product manuals