CircuPool Universal UL25 - TROUBLESHOOTING CONTINUED; LED Indicators and Error Codes; Water Leaks and Connections; Cell Buildup and Performance Issues

CircuPool Universal UL25
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Check Salt LED is on /
S-LO on screen /
Hi Salt LED is on/
S-HI on screen
Salinity is out of range
Manually verify salinity (see pages 6-7).
Loose Cell connection, or Cell is dirty or
clogged
Inspect and clean Cell if necessary.
Incorrect Cell Version set
Verify Cell Version in system status menu
No Flow LED is on
Insufficient water flow or air bubbles
This may happen temporarily if there is air in the
lines at initial startup. Check water level, pump
cavitation, air or blockages in plumbing, and all
valves & seals. Clean filters & strainers. Ensure
at least 25-30 GPM flow rate.
Incorrect Installation
Verify correct orientation, cable is plugged in, 6-
12" of straight pipe before Flow Switch
Water leak
O-Ring improperly seated
Ensure O-Rings are clean and in good condition.
Threaded collars are cross-threaded or
pipes are misaligned
Inspect threads for damage, ensure that each
screws back on without resistance.
Real-Time Salinity and Cell
current read zero
Zero reading displayed is normal during
rest cycle
No action is required. Will rise after rest cycle or
raising output
Incorrect voltage / loose cell connection
Have professional check wiring.
Incorrect Cell Version set
Verify Cell Version in Status Menu.
No Flow, Lo Salt, High Salt, or Cell Maint.
LED on
See previous sections.
Cell frequently has mineral
buildup
This is due to imbalanced water chemistry
and a high Saturation Index
Ensure that your Saturation Index is at or near
zero, in order to avoid damage or premature
Cell failure. (page 8)
Cell never or rarely has mineral
buildup
Water may be corrosive due to imbalanced
water chemistry and a low Saturation Index
Ensure that your Saturation Index is at or near
zero, in order to avoid damage or premature
Cell failure. (page 8)
HOT or COLD on screen/
GENERATE light flashing
Water temperature is too hot or cold for
operation
Check operation of heater, or turn off until water
temp is below 130-140°F or is above 50-55°F and
more sanitation is needed.
Cell is dirty or clogged
Clean Cell (see page 12).
Damaged Cell or Cell cable
Contact manufacturer.
For more information or troubleshooting, visit www. circupool.com/help