Figure 144: Installing Ball Stud Assemblies on the Cisco ASR 9006 Router (Shown with Version 1 Power System)
Step 3 Attach the door to the upper chassis panel (see the figure below) using two hex nuts per side to secure the
door hinges to the panel. Tighten the hex nuts to a torque of 4 in-lb (0.45 N-m).
Do not overtighten the hex nuts. They can be broken through overtightening.
Caution
When opening the door, be sure to grasp the center of the door to pull it open. Do not open the door
by pulling on a corner or side of the door frame.
Caution
Figure 145: Installing the Optional Accessory Door on the Cisco ASR 9006 Router
Cisco ASR 9000 Series Aggregation Services Router Hardware Installation Guide
136
Unpacking and Installing the Chassis
Installing Optional Chassis Accessories on the Cisco ASR 9006 Router

Table of Contents

Other manuals for Cisco ASR 9006

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 9006 and is the answer not in the manual?

Cisco ASR 9006 Specifications

General IconGeneral
Chassis TypeModular
Rack Units10 RU
Slots6
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Relative Humidity5% to 95% non-condensing
Power SupplyAC or DC
CoolingFront-to-back airflow
Input Voltage100-240 VAC or -48 to -60 VDC
Supported ProtocolsIPv4, IPv6, MPLS, L2VPN, L3VPN
Interfaces10GE, 40GE, 100GE
Management InterfacesEthernet, Console, Auxiliary