• 1.73 x 9.45 x 17.5 in. (4.4 x 24 x 44.5 cm) (Cisco
Catalyst 2960L-SM-24TS)
• 1.73 x 10.45 x 17.5 in. (4.4 x 26.5 x 44.5 cm)
(Cisco Catalyst 2960L-SM-24PS)
• 1.73 x 9.45 x 17.5 in. (4.4 x 24 x 44.5 cm) (Cisco
Catalyst 2960L-SM-48TS)
• 1.73 x 11.5 x 17.5 in. (4.4 x 29.2 x 44.5 cm)
(Cisco Catalyst 2960L-SM-48PS)
• 1.73 x 9.45 x 17.5 in. (4.4 x 24 x 44.5 cm) (Cisco
Catalyst 2960L-SM-24TQ)
• 1.73 x 10.45 x 17.5 in. (4.4 x 26.5 x 44.5 cm)
(Cisco Catalyst 2960L-SM-24PQ)
• 1.73 x 9.45 x 17.5 in. (4.4 x 24 x 44.5 cm) (Cisco
Catalyst 2960L-SM-48TQ)
• 1.73 x 11.5 x 17.5 in. (4.4 x 29.2 x 44.5 cm)
(Cisco Catalyst 2960L-SM-48PQ)
Dimensions (H x D x W)
Environmental Specifications
Environmental Ranges
23 to 113°F (–5 to 45°C) up to 5,000 ft (1500 m)
23 to 104°F (–5 to 40°C) up to 10,000 ft (3000 m)
Operating temperature
3
-13º to 158ºF (-25º to 70ºC) up to 15,000 ft (4500 m)Storage temperature
5% to 90% (noncondensing) at 40ºCOperating relative humidity
5% to 95% (noncondensing) at 65ºCStorage relative humidity
Up to 15,000 ft (4500 m)Storage altitude
3
Minimum ambient temperature for cold start is 32°F (0°C)
• When using Cisco Catalyst 2960L-SM-24TS, Cisco Catalyst 2960L-SM-24PS and Cisco Catalyst
2960L-SM-48TS switches with GLC-T SFP module, the thermal limitations are as follows:
• Up to 5000 feet, the operating temperature should not exceed 40°C.
• Up to 10000 feet, the operating temperature should not exceed 35°C.
• When using Catalyst 2960L-SM-24TQ, Catalyst 2960L-SM-24PQ and Catalyst 2960L-SM-48TQ with
SFP-10G-ER or SFP-10G-ER-S SFP+ module, the thermal limitations are as follows:
• Up to 5000 feet, the operating temperature should not exceed 40°C.
• Up to 10000 feet, the operating temperature should not exceed 35°C.
Cisco Catalyst 2960-L Smart Managed Series 24-Port and 48-Port Switch Hardware Installation Guide
42
Technical Specifications
Environmental Specifications