Reconfiguring Forward Signal Routing
3x4-1, 2, 4 Forward Configuration Module
Three receivers each feeding one/two/three/four RF output ports. RCVR 1 feeds
Ports 5/6. RCVR 2 feeds Port 4. RCVR 4 feeds Ports 1/2/3.
Note: The 3x4-1, 2, 4 FCM can only be used with the 4-way RF amplifier module.
The following diagram illustrates forward path signal flow in this module.