1-67
Cisco MDS 9148S Multilayer Switch Hardware Installation Guide
OL-20185-01
Chapter 1      Cable and Port Specifications
    Supported Power Cords and Plugs
Supported Power Cords and Plugs
A separate power cord is provided for each power supply. Standard power cords or jumper power cords 
are available for connection to a power distribution unit having IEC 60320 C13 outlet receptacles. The 
jumper power cords, for use in cabinets, are available as an option instead of the standard power cords.
Power Cords
The standard power cords have an IEC C15 connector on the end that plugs into the switch. The optional 
jumper power cords have an IEC C15 connector on the end that plugs into the switch, and an IEC C14 
connector on the end that plugs into an IEC C13 outlet receptacle.
Note Only the standard power cords or jumper power cords provided with the switch are supported.
Note If you do not order the optional power cord with the system, you are responsible for selecting the 
appropriate power cord for the product. Using a non-compatible power cord with this product may result 
in electrical safety hazard. Orders delivered to Argentina, Brazil, and Japan must have the appropriate 
power cord ordered with the system.
Figure 1-3 shows the supported plugs for the Cisco MDS 9100 Series power supplies.