EasyManua.ls Logo

Cisco NCS 1001 - Protection Switching Module

Cisco NCS 1001
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XFP for OSC and additional OTDR feature1
SFP for OSC (Optical Service Channel)2
Status LED3
Service Channel input and output port [OSC - RX, TX]4
PRE and BST amplifier inputs and output ports
[L (LINE) - RX, TX]
[C (COM) - RX, TX]
[COM - TX CHECK]
5
The following table describes the mapping of controllers and optical ports for the optical amplifier module.
Optical PortsController
COM-RX (booster input)
COM-TX (preamplifier output)
Ots 0/slot/0/0
LINE-RX (preamplifier input)
LINE-TX (booster output)
Ots 0/slot/0/1
OSC-RX
OSC-TX
Ots 0/slot/0/2
COM-CHECKOts 0/slot/0/3
Protection Switching Module
The protection switching module (NCS1K-PSM) provides the following functionality.
In TX section:
Splits input optical channels to both working and protection lines.
Forces the switch in the remote site by opening one of the two line paths (by putting the related
VOA in AVS).
In RX section:
Selects the signals from working or protection line. Each line is monitored through a PD.