1-3
Cisco UCS Server Configuration Utility, Release 5.0
Chapter 1 Overview
Supported Peripheral Devices
• UCS-C220 M4
• UCS-C460 M4
Supported Peripheral Devices
Table 1-1 shows the SIOC and LSI controller devices supported by UCS-SCU.
Note The UCS-SCU RAID configuration utility detects the physical drivers only once when you enter this
function area after the system is rebooted. Do not remove or add hard disk drivers while navigating
within this function area.
Table 1-1 SIOC and LSI Controller Devices
Server SIOC LSI Controller RAID Levels Supported
C3160 Intel I350,
Cisco VIC
1227
• Storage Servers
(SLOT-MEZZ)
• 0,1,5,6,10,50,60
Note Single virtual drive should
not contain more than
thirty-two number of
HDDs.
S3260 M3,
S3260 M4
UCSC-C326
0-SIOC
• Storage Servers
(SLOT-MEZZ)
• 0,1,5,6,10,50,60
Note Single virtual drive should
not contain more than
thirty-two number of
HDDs.
C22, C24 Intel I350
• 9265-8i
• 9240-8i
• 9220-4i
• 9220-8i
• 0, 1, 5, 10
C220, C240 Intel I350
• LSI 9266-8i
• Cisco UCSC RAID SAS
2008M-8i
• LSI Embedded MegaRAID
• 0, 1, 5, 6,10, 50, 60
• 0, 1, 5, 10, 50
• 0, 1, 5 (if TSOC is installed in
the server), 10
C220 M4 Intel I350
• 3108
• LSI Embedded MegaRAID
• 0, 1, 1E, 5, 6, 10, 50, and 60
C240 M4 Intel I350
• 3108 • 0, 1, 1E, 5, 6, 10, 50, and 60
C460 M4 X540
• 3108
• 9361
• 0, 1, 1E, 5, 6, 10, 50, and 60
• 0, 1, 5, 6, 10, 50, and 60