Cisco XR 12000 Series Router Ethernet Line Card Installation
OL-7861-01
Line Card Memory
Figure 55 SODIMM with Key in Face-up Position
Step 7 The SODIMM must be lined up at a 45-degree angle. (See Figure 56a.)
Note When the key is in the face-up position, the metal traces on the left side of the key measure 0.9 inch
(23.20 mm). The metal traces on the right side of the key measure 1.29 inches (32.80 mm). The
SODIMM can not be inserted until the keys are lined up properly.
Step 8 Place both thumbs at the end of the socket and use your index fingers to guide the module into the socket
until it is fully seated.
Be sure that your index fingers are located on the outer corners of the SODIMM to maintain even
pressure when the module is being seated in the socket.
Figure 56 Inserting a 144-pin SODIMM Module
Step 9 Gently press the SODIMM down using your index fingers, distributing even pressure across the module
until it locks into the tabs. (See Figure 56b.)