7
EtherNet/IP Connection Procedure
3
Connect Actuator and Resolver
cable connector with a Resolver
cable.
Connect Actuator and Actuator
output terminal with a Motor
cable.
4
Connect Switching hub and
EtherNet/IP connector with a
LAN cable.
Connect Switching hub power
supply to Switching hub.
Connect the serial connector on
Personal computer and
RS-232C connector with an
RS-232C cable.
6
Check that the safety function is
invalidated.
Check that jumpers are
connected to Safety function
terminal.
*Since the intention of this guide
is to verify the network
connection, the safety function
is left invalid.
*Refer to 3.2.6. Wiring for Safety
Function of the INSTRUCTION
MANUAL ABSODEX AX
SERIES TS TYPE TH TYPE
XS TYPE (SMF-2006-A) for
wiring to Safety function
*A jumper is connected to Safety function terminal to
invalidate the safety function when ABSODEX Driver is
shipped from the factory.
computer
RS-232C cable
Switching hub power supply