STEP 1U
STEP 2U
STEP 3U
Set Time of Day
The user can also set the time of day. Time of day should only need to be set if the battery has been depleted because of extended
power outages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will ash on and
off which indicates the time of day should be reset. The non rechargeable battery should also be replaced.
STEP 1U – Press CLOCK.
STEP 2U - Current Time (hour): Set the hour of the day using W or V buttons. AM/PM toggles
after 12. Press NEXT to go to Step 3U.
STEP 3U - Current Time (minutes): Set the minutes of the day using W or V buttons. Press
NEXT to exit Set Time of Day. Press REGEN to return to previous step.
RETURN TO NORMAL MODE
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. An example of a time with
low water usage is when a household is asleep. If there is a demand for water when the system is
regenerating, untreated water will be used.
When the system begins to regenerate, the display will change to include information about the
step of the regeneration process and the time remaining for that step to be completed. The system runs through the steps
automatically and will reset itself to provide treated water when the regeneration has been completed.
Manual Regeneration
Sometimes there is a need to regenerate the system sooner
than when the system calls for it, usually referred to as manual
regeneration. There may be a period of heavy water usage because
of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regeneration time, when the regeneration time option is set to
“DELAYED REGEN” or “DELAY + IMMEDIATE”, press and release “REGEN”. The words “REGEN TODAY” will
periodically be shown on the display to indicate that the system will regenerate at the preset delayed regeneration time. If you
pressed the “REGEN” button in error, pressing the button again will cancel the request. Note: If the regeneration time option
is set to “IMMEDIATE” there is no set delayed regeneration time so “REGEN TODAY” will not activate if “REGEN” button
is pressed.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system will begin
to regenerate immediately. The request cannot be cancelled.
Note: For softeners, if brine tank does not contain salt, ll with salt and wait at least two hours before regenerating.