Page #54 background image
16
Clean Track
®
12
06-2
SOLUTION SYSTEM
FORM NO. 56041658
WIRING DIAGRAM
S1
ROCKER SWITCH
S2
M1
MOTOR, VACUUM
AMP = 7.7
M3
MOTOR, PUMP
AMP = 0.6
L1
SOLENOID VALVE
AMP = .06
D1
DIODE BRIDGE
F1
CIRCUIT BREAKER, 3 A.
HANDLE SWITCH
WHT
GRN
BLK
BLK
1
2
3
5
4
6
BLK
1
2
3
2
1
2
1
2
1
3
1~
1
1
2
#10 RING TERMINAL (FASTEN TO CONROL PANEL)
POWER CORD
G
N
L
M
M
GRN
WHT
BLK
GRN
3
GRN
BLK
BLK
BLK
M
M2
RED
BLK
GRN
E_GND
MOTOR, BRUSH
AMP = 2.3
-
+
+
-
~
~
1~
BLK
WHT
BLK
BLK
BLK
WHT
GRN
GRN
BLK #1 (4 Cond Cable)
BLK #3 (4 Cond Cable)
BLK
BLK #2 (4 Cond Cable)
BLK #1 (2 Cond Cable)
BLK #2 (2 Cond Cable)
GRN/YEL (4 Cond Cable)
1
2
3
5
4
6
8
7
10
9
X1
N
N
N