18
Draining the reservoir
CAUTION! It is important to drain the reservoir before storage.
1 Switch the air compressor off, by pressing down the red On/Off button, and
remove the plug from the mains supply.
• Place a suitable container beneath the compressor to catch any
condensation.
2 Carefully undo the drain valve anti-clockwise until you hear a hissing noise,
this is the reservoir depressurising.
• When the gauge indicates zero and the hissing has stopped, tighten the
drain outlet nut again.
OPERATING INSTRUCTIONS
Figure 10
Drain outlet